Armor-FloTM meters with integral transmitters provide an ideal combination – a local mechanical flow rate indicator independent of electrical supply with a 4-20 mA two wire loop powered signal output. The output signal is linear within the middle 80% of the range. A response curve is furnished with each flowmeter. Simple design, rugged construction and good value make this the ideal utility fluid flowmeter.

  • Instantaneous local flow rate measurement.
  • Local flow rate indication requires no power.
  • Flow proportional signal output.
  • Broad range of materials available.
  • Use in horizontal or vertical piping systems.
  • Individually calibrated for fluid and operating conditions.
  • User selectable 10:1 turndown flow ranges. (“See Meter Rangeability Sizing Tables”)
  • User selectable units of measure-including dual units of measure.
  • No floats to get stuck, tubes to break or dynamic seals to leak.
  • Low pressure loss.
  • Simple design with few parts for long service life.

flex-flo-principal-operationsThe Armor-FloTM body housing has a variable internal volume which enlarges from the inlet to the outlet. The primary sensor is a tempered alloy vane with one end affixed to the apex of the meter housing. As the flow rate changes, the vane is flexed in direct proportion. A Teflon® encapsulated magnet links the vane position with the
pointer in the indicator housing and the signal output/switch circuit. All adjustments and electrical connections are accessible from the front of the meter housing.

The 1⁄2″, 3⁄4″ and 1″ connections typically have female threaded ends. Sizes 1 1⁄4″ through 12″ utilize an integral bypass housing permitting larger connection sizes in the format of a spool
with a consistant 12″ end to end dimension. In addition, it permits a wide variety of connection types which include threaded, flanged, grooved-ends and tri-clamp.

armor-flo-principal-operation2

Accuracy: ±2% full scale

Repeatability: ±1% full scale

Scales: Direct reading
Resolution: Maximum-30 division/Minimum-15 divisions

Rangeability: 10 to 1 turndown

Transmitter: Accuracy: ± 2% full scale Repeatability: ± 0.5% full scale Permissible load: Rmax= 750 Ω Temperature limits: 0-85°C (32-185°F) Environmental: NEMA 4/NEMA 4x

Materials of Construction:
Housing: Aluminum, brass, 316 stainless steel
Shunt: As housing or carbon steel
Window: Tempered glass or polycarbonate
Vane: Cobalt/chromium/nickel alloy with Teflon® encapsulated magnet
“O” rings: Buna-n, ethylene propylene, Viton® or perfluoroelastomer

Piping Connections:

  • 1/2” to 1″ NPT Female
  • 1 1/4” to 4″ NPT male
  • 1 1/2” to 3″ Tri-clamp
  • 1 1/4” to 6″Grooved
  • 1 1/4” to 6″ Beveled
  • 1/2” to 8″ 150# /300# RF/FF ANSI Flanges (carbon stl)
  • 1/2” to 8″ 150# RF ANSI Flanges (stainless stl)
  • 1/2” to 6″ 150# RF ANSI Flanges (aluminum)
  • 1/2” to 6″ 150# FF ANSI Flanges (brass)
  • 15 to 25 mm DIN 2999/BS21/ISO R7 Female threaded
  • 15 to 150 mm DIN PN 10 Flanges (316 stainless stl & carbon stl)

screen-shot-2016-10-15-at-2-34-28-pm

Pressure Limits:

  • 1 Housing (aluminum) 0, 1 or 5 Shunt-200 psig (13.8 bar)
  • 2 Housing (brass)
    • 0 Shunt-400 psig (27.6 bar)
    • 2 or 5 Shunt-200 psig (13.8 bar)
  • 6 Housing (316 stainless stl)
    • 0 Shunt-400 psig (27.6 bar)
    • 5 or 6 Shunt-200 psig (13.8 bar)
    • 7 or 8 Shunt-400 psig (27.6 bar)
  • 8 Housing (high pressure 316 stainless stl) 0 Shunt-1000 psig (69 bar)

Temperature Limits: 0 to 85°C (32 to 185°F)